ZHANG Jun, JIANG Wei, NING Zhi-ming, WEI Chao-shuai. Determination of 4 dissolved metals in seawater by direct dilution—inductively coupled plasma mass spectrometry method[J]. Chinese Journal of MARINE ENVIRONMENTAL SCIENCE, 2023, 42(3): 466-470. DOI: 10.12111/j.mes.2022-x-0107
Citation: ZHANG Jun, JIANG Wei, NING Zhi-ming, WEI Chao-shuai. Determination of 4 dissolved metals in seawater by direct dilution—inductively coupled plasma mass spectrometry method[J]. Chinese Journal of MARINE ENVIRONMENTAL SCIENCE, 2023, 42(3): 466-470. DOI: 10.12111/j.mes.2022-x-0107

Determination of 4 dissolved metals in seawater by direct dilution—inductively coupled plasma mass spectrometry method

More Information
  • Received Date: April 27, 2022
  • Revised Date: July 24, 2022
  • Accepted Date: July 24, 2022
  • Available Online: June 13, 2023
  • A method was established for the simultaneous determination of Cr, Cu, As, Cd by inductively coupled plasma mass spectrometry (ICP-MS) after diluting seawater samples by 10 times. The method uses self-made standard seawater as the matrix matching solution, He gas as the collision gas, and 115In as the internal standard substance. The linear correlation coefficients of Cr, Cu, As and Cd were above 0.9990 in the concentration range of 0 ~ 0.200 μg/L. The detection limit of theses metals was 0.049 μg/L(Cr), 0.027 μg/L(Cu), nd Cd are above 0.9990 in the concentration range of 0 ~ 0.200 μg/L. The detection limit of theses metals was 0.049 μg/L(Cr), 0.027 μg/L(Cu), 0.083 μg/L (As), 0.009 μg/L (Cd). The recovery range of NASS-6 and actual seawater samples were between 92.1% and 106.8%. The detection limit, accuracy, precision and signal long-term stability of this method can meet the requirements of Chinese specification for marine monitoring. This method has been used in the analysis of seawater samples in Weizhou island, Guangxi. The results show a small deviation compared with the FAAS method, so it can be used as the conventional detection method of trace metals in seawater, such as Cr, Cu, As, Cd.

  • [1]
    王增焕, 王许诺. 萃取分离-原子吸收光谱法测定海水中镉铜铅锌铬镍[J]. 冶金分析, 2014, 34(2): 44-47.
    [2]
    侯 静, 弓振斌, 郭旭明, 等. 流动注射-氢化物发生-非色散原子荧光光谱法直接测定海水中的砷(Ⅲ)和砷(Ⅴ)的研究[J]. 分析试验室, 2000, 19(6): 13-16. doi: 10.3969/j.issn.1000-0720.2000.06.004
    [3]
    殷小琴. 氢化物发生-原子荧光光谱法测定海水中痕量硒[J]. 海洋环境科学, 2008, 27(5): 517-519. doi: 10.3969/j.issn.1007-6336.2008.05.028
    [4]
    尚 宇. ICP-MS在环境监测中的研究新进展[J]. 浙江化工, 2018, 49(12): 38-41. doi: 10.3969/j.issn.1006-4184.2018.12.011
    [5]
    王晴萱. 海水重金属监测分析方法比较研究[D]. 大连: 大连理工大学, 2015.
    [6]
    苏庆梅, 秦 伟. 海水中重金属铅的检测方法研究进展[J]. 海洋科学, 2009, 33(6): 105-111.
    [7]
    刘 瑶, 宋金明, 孙玲玲, 等. 氢氧化镁共沉淀富集分离ICP-MS测定海水中的稀土元素[J]. 海洋环境科学, 2019, 38(2): 303-309. doi: 10.12111/j.cnki.mes20190220
    [8]
    MOOS S B, BOYLE E A. Determination of accurate and precise chromium isotope ratios in seawater samples by MC-ICP-MS illustrated by analysis of SAFe Station in the North Pacific Ocean[J]. Chemical Geology, 2019, 511: 481-493. doi: 10.1016/j.chemgeo.2018.07.027
    [9]
    王丹红, 林建杰, 蔡春平, 等. 在线分离富集-ICP-MS法直接测定海水中痕量稀土元素[J]. 分析试验室, 2016, 35(7): 773-776. doi: 10.13595/j.cnki.issn1000-0720.2016.0177
    [10]
    SORIANO E, YUSÀ V, PASTOR A, et al. Dynamic reaction cell inductively couple plasma-mass spectrometry optimization for seawater analysis[J]. Microchemical Journal, 2018, 137: 363-370. doi: 10.1016/j.microc.2017.11.015
    [11]
    KARASINSKI J, BULSKA E, WOJCIECHOWSKI M, et al. High precision direct analysis of magnesium isotope ratio by ion chromatography/multicollector-ICPMS using wet and dry plasma conditions[J]. Talanta, 2017, 165: 64-68. doi: 10.1016/j.talanta.2016.12.033
    [12]
    母清林, 方 杰, 佘运勇, 等. 在线稀释/预浓缩-电感耦合等离子体质谱法分析海水中11种痕量元素[J]. 分析化学, 2015, 43(9): 1360-1365. doi: 10.11895/j.issn.0253-3820.150474
    [13]
    谭赛章, 张昊飞, 吴康康, 等. 自动化树脂分离富集装置与ICP-MS联用在海水痕量金属元素分析中的应用[J]. 上海海洋大学学报, 2019, 28(5): 662-670. doi: 10.12024/jsou.20181202457
    [14]
    JJF 1159-2006, 四极杆电感耦合等离子体质谱仪校准规范[S].
    [15]
    王德君, 贾肇基. 中国系列标准海水的制备[J]. 海洋技术, 1988 (2): 19-27.
    [16]
    GB 17378.2-2007, 海洋监测规范 第2部分: 数据处理与分析质量控制[S].
    [17]
    李 萍, 莫海连, 郭 钊. 2016年北部湾近岸海域海水环境质量评价[J]. 海洋湖沼通报, 2019 (1): 54-64.
    [18]
    GB 17378.4-2007, 海洋监测规范 第4部分: 海水分析[S].
  • Related Articles

    [1]JIA Liangliang, DONG Lingyun, FAN Peidong, HAO Xinghua, WANG Yanjie. Determination of twenty-two trace elements in seawater by solid phase extraction-inductively coupled plasma mass spectrometry[J]. Chinese Journal of MARINE ENVIRONMENTAL SCIENCE, 2024, 43(3): 458-464. DOI: 10.12111/j.mes.2023-x-0200
    [2]JIN Fei, WANG Ying, CONG Yi, ZHANG Mingxing, LI Zhaochuan, LOU Yadi, YAO Ziwei, WANG Juying. Research on environmental priority pollutants in seawater of China by COMMPS and DYNAMEC methods[J]. Chinese Journal of MARINE ENVIRONMENTAL SCIENCE, 2023, 42(6): 892-900. DOI: 10.12111/j.mes.2023-x-0094
    [3]SUN Ling-ling, SONG Jin-ming, LIU Yao, YU Ying, SUN Xuan. Simultaneous determination of molybdenum and other heavy metals in Mytilus edulis by inductively coupled plasma mass spectrometry with quadrupole collision cell technology[J]. Chinese Journal of MARINE ENVIRONMENTAL SCIENCE, 2020, 39(3): 453-459. DOI: 10.12111/j.mes20200320
    [4]GAO Tian-ci, GAO Xue-lu, XING Qian-guo, YANG Bo, LU Yu-xi. Trace metal contents in Enteromorpha and Sargassum from South Yellow Sea, China[J]. Chinese Journal of MARINE ENVIRONMENTAL SCIENCE, 2020, 39(2): 177-182, 210. DOI: 10.12111/j.mes20200202
    [5]WEI Ji-fang, WANG Rong-yuan, WANG Wei, ZHANG Xin-xing, DENG Chun-mei, YAO Hai-yan, DING Kai, ZHANH Meng-meng. Study on efficiency calibration of 137Cs γ-spectrum analysis in seawater[J]. Chinese Journal of MARINE ENVIRONMENTAL SCIENCE, 2019, 38(3): 342-346, 352. DOI: 10.12111/j.mes20190304
    [6]LIU Yao, SONG Jin-ming, SUN Ling-ling, YU Ying, SUN Xuan. Determination of trace rare earth elements in seawater by ICP-MS with Mg(OH)2 co-precipitation treatment[J]. Chinese Journal of MARINE ENVIRONMENTAL SCIENCE, 2019, 38(2): 303-309. DOI: 10.12111/j.mes20190220
    [7]ZHANG Cui-qin, LI Li, YANG Ru-jun. Research progress on determination of the speciation of dissolved Cu, Pb, Zn and Cd in seawater by stripping voltammetry[J]. Chinese Journal of MARINE ENVIRONMENTAL SCIENCE, 2018, 37(1): 151-160. DOI: 10.13634/j.cnki.mes20180123
    [8]ZHENG Wen-jing, HAN Yu, QIN Chuan, ZHANG Gui-ling. Continuous underway measurements of sea surface O2/Ar and pCO2 by membrane inlet mass spectrometry[J]. Chinese Journal of MARINE ENVIRONMENTAL SCIENCE, 2016, 35(4): 611-617. DOI: 10.13634/j.cnki.mes20160421
    [9]QIAO Ling, ZHEN Yu, MI Tie-Zhu. Review of the brown tides caused by Aureococcus anophagefferens[J]. Chinese Journal of MARINE ENVIRONMENTAL SCIENCE, 2016, 35(3): 473-480. DOI: 10.13634/j.cnki.mes20160324
    [10]NI Zhi-xin, ZHANG Xia, CAI Wei-xu, LIU Jing-qin, HUANG Xiao-ping. Distribution, speciation and risk assessment of trace metals in surface sediment of the Zhujiang estuary[J]. Chinese Journal of MARINE ENVIRONMENTAL SCIENCE, 2016, 35(3): 321-328. DOI: 10.13634/j.cnki.mes20160301
  • Cited by

    Periodical cited type(3)

    1. 韩梅,张威,贾娜,张辰凌,孔祥科. 生物炭富集-电感耦合等离子体质谱法测定海水中的痕量铅铜. 岩矿测试. 2024(02): 281-288 .
    2. 贾亮亮,董凌云,范培栋,郝兴华,王艳洁. 固相萃取-电感耦合等离子体质谱法测定海水中22种痕量金属元素. 海洋环境科学. 2024(03): 458-464 . 本站查看
    3. 李维涵,李鹰,李剑,徐岳,刘岩,付罗岭. 氩气在线稀释—电感耦合等离子体质谱法测定土壤中10种痕量元素. 理化检验-化学分册. 2023(07): 759-763 .

    Other cited types(1)

Catalog

    Article Metrics

    Article views (414) PDF downloads (23) Cited by(4)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return